Specifications
Supply Voltage
Nominal voltage: 120 V ac, 60 Hz in North America
Nominal voltage: 100 V ac to 277 V ac, 50/60 Hz outside North America
Power factor: > 0.95 at 120 V ac and > 0.90 at 230 V ac
Total harmonic distortion (THD): < 20%
See electrical characteristics on product label
Supply Current
Lighted Length
(mm)
Max. Current Draw
(A) at 90 V ac
Typical Current Draw (A)
120 V ac 230 V ac
550 0.425 0.270 0.135
1100 0.850 0.540 0.250
Supply Protection Circuitry
Protected against transient voltages
Light Characteristics
Daylight White and Warm White Efficacy: 110 lumens/watt typical at 120 V
ac at 25 °C (77 °F)
CRI: 82, typical
Color Dominant Wavelength
(nm) or Color
Temperature (CCT)
Lighted Length Lumens
(Typical at 25 °C)
550 mm 1100 mm
Daylight
White
5000 K (±300 K) 3510 7150
Warm
White
3000 K (+225 K, -125 K) 3510 7150
Green 525 nm 1430 2975
Red 625 nm 745 1545
Yellow 590 nm 620 1295
Blue 470 nm 405 840
Test Data
LM-79, LM-80, TM-21
Environmental Rating
IEC IP40
LED Lifetime
Lumen Maintenance - L
70
When operating within specifications, output will decrease less than 30%
after 50,000 hours.
Switch/Dimming Knob
On/Off Switch and dimming knob, dimmable to 15% intensity
Construction
Anodized aluminum housing, polycarbonate window and end caps, and
stainless steel mounting brackets
Spacing Criterion
Vertical: 1.20
Horizontal: 1.32
Connections
Integral custom quick disconnect (connecting cordset required)
Mounting
Snap mount brackets included (two for the 550 mm model; three for the
1100 mm model)
Compatible with integral 45 mm aluminum framing mounting slots
Operating Temperature
550 Lighted Length: –35 °C to +50 °C (–31 °F to +122 °F) for 24 hours per
day for 5 years of operation
1100 Lighted Length: –40 °C to +45 °C (–40 °F to +113 °F) for 16 hours per
day for 5 years of operation; or –40 °C to +35 °C (–40 °F to +95 °F) for 24
hours per day for 5 years of operation
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC
60068-2-6
Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27
Application Notes
When connecting continuous run/cascadable lights in series, see table for
maximum number of units. Do not exceed a maximum wiring distance of
100 m (328 ft) in the main power cable and any cascading cables.
Maximum Unit Limit (when using both model lengths)
550 mm Lights 1100 mm Lights
10 0
8 1
6 2
4 3
2 4
0 5
For example, if you use four 550 mm lights, you may add up to three 1100
mm lights within the same continuous run.
Certifications
Spacing Criteria (SC)
The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing
criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between
fixtures).
Luminaire Spacing = SC × Height to Illuminated Plane
The mounting height is the distance from the fixture to the surface you are lighting.