Installing the WLB92 Industrial LED Light Bar (AC Quick Disconnect Models)
Figure 1. Attaching the snap brackets (step 6) Figure 2. Installing the cascade cover (step 9)
1. Attach the snap brackets to the light.
2. Select a suitable horizontal or vertical dry mounting location. The maximum distance to the power receptacle cannot be
farther than the length of the power cord used.
3. Place the light in the mounting location and mark the positions of the snap bracket mounting holes.
4. Remove the brackets from the light.
5. Drill the holes and use appropriate screws to secure the snap bracket to the mounting location.
6. Snap the light onto the brackets.
7. When installing cascading lights, repeat steps 1 through 6 to mount additional lights. See the application note in the
Specifications
section for the maximum cascaded lights and maximum allowed cable run when choosing mounting
locations.
8. Connect the cascaded lights together using an applicable cordset (see
Accessories
(p. 5)).
9. Install the supplied cover over the output connector on the last light in the chain.
10. Plug the power cord from the first light into the wall outlet. A 3 m (10 ft) cord is available for applications requiring a longer
cord for cabinet installations.
CAUTION: To reduce the risk of fire, electrical shock, or injury to personal:
Use only insulated staples or plastic ties to secure cords
Route and secure cords so that they will not be pinched or damaged when the cabinet is pushed to the
wall
Position the portable cabinet light with respect to the cabinet so the lamp replacement markings are
able to be read during relamping
Do not recess into ceilings or soffits
Do not conceal the cords. The National Electrical Code (NEC) does not permit cords to be concealed
where damage to insulation may go unnoticed. To prevent fire danger, do not run cords behind walls,
ceilings, soffits, or cabinets where it may be inaccessible for examination. Cords should be visually
examined periodically and immediately replaced when any damage is noted.
CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305
mm by 305 mm by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305
mm by 1350 mm.
WLB92 Industrial LED Light Bar (AC Quick Disconnect)
2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 183984 Rev. H
购买、咨询产品请填写询价信息:(3分钟左右您将得到回复)
询价型号*数量*批号封装品牌其它要求
删除
删除
删除
删除
删除
增加行数
  •  公司名:
  • *联系人:
  • *邮箱:
  • *电话:
  •  QQ:
  •  微信:

  • 关注官方微信

  • 联系我们
  • 电话:13714778017
  • 周一至周六:9:00-:18:00
  • 在线客服:

天天IC网由深圳市四方好讯科技有限公司独家运营

天天IC网 ( www.ttic.cc ) 版权所有©2014-2023 粤ICP备15059004号

因腾讯功能限制,可能无法唤起QQ临时会话,(点此复制QQ,添加好友),建议您使用TT在线询价。

继续唤起QQ 打开TT询价