W25Q80BL
Publication Release Date: July 08, 2010
- 65 - Preliminary - Revision C
10.6 AC Electrical Characteristics
SPEC
DESCRIPTION SYMBOL ALT
MIN TYP MAX
UNIT
Clock frequency for all instructions
except Read Data instruction (03h)
2.3V-3.6V VCC & Industrial Temperature
F
R
f
C
D.C. 50 MHz
Clock frequency for Read Data instruction (03h) fR D.C. 25 MHz
Clock High, Low Time
for all instructions except Read Data (03h)
tCLH1,
t
CLL1
(1)
7 ns
Clock High, Low Time
for Read Data (03h) instruction
tCRLH,
t
CRLL
(1)
13 ns
Clock Rise Time peak to peak tCLCH
(2)
0.1 V/ns
Clock Fall Time peak to peak tCHCL
(2)
0.1 V/ns
/CS Active Setup Time relative to CLK tSLCH tCSS 5 ns
/CS Not Active Hold Time relative to CLK tCHSL 5 ns
Data In Setup Time tDVCH tDSU 2 ns
Data In Hold Time tCHDX tDH 5 ns
/CS Active Hold Time relative to CLK tCHSH 5 ns
/CS Not Active Setup Time relative to CLK tSHCH 5 ns
/CS Deselect Time (for Array Read Æ Array Read) tSHSL1 tCSH 50 ns
/CS Deselect Time (for Erase or Program Æ Read
Status Registers)
Volatile Status Register Write Time
t
SHSL2 tCSH 100
50
ns
Output Disable Time tSHQZ
(2)
tDIS 7 ns
Clock Low to Output Valid tCLQV1 tV1 9 ns
Clock Low to Output Valid (for Read ID instructions) tCLQV2 tV2 9 ns
Output Hold Time tCLQX tHO 0 ns
/HOLD Active Setup Time relative to CLK tHLCH 5 ns
Continued – next page