143
Assembling Procedure
After assembling, please make
sure if the contact is installed
as shown in the left by pulling
the cable slightly.
Procedure for Contact Extraction
In case of extracting a contact from the housing in insertion
error or in circuit change, follow the steps as shown below.
1. Hold the Contact Extractor, placing the tip of the
Extractor on the tip of a contact, then insert it
between the contact and the housing, following to
the Fig. 1.
2. When the tip of the Extractor comes into contact
with a stepped part in the housing, the spring will
come off from the stepped part with a snap which
is felt. Then, extract the contact by pulling the wire.
3. Above Fig. 1 and Fig. 2 show how to extract a con-
tact from socket housing. The same procedure can
be employed to extract a contact from pin housing.
4. When the extracted contact is installed again in the
housing, do not forget to raise up the contact
spring to the original position.
Fig. 1 Fig. 2
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.