Output Protection Circuitry
Protected against false pulse on power-up, short-circuit protected
Output Response Time
Opposed Mode: 1.3 ms ON; 900 µs OFF
All Other Modes: 700 µs ON/OFF
NOTE: 120 ms delay on power-up; outputs do not conduct during this time.
Indicators
One Yellow and one Green LED (see Figure 1)
Construction
Polarized Retro Models: Thermoplastic elastomer housing with glass lens
All Other Standard Models: Thermoplastic elastomer housing with
polycarbonate lens
Chemical-Resistant Models: Housing encased in PFA jacket; cable encased
in 3/16 in O.D. PFA tubing
Output Ratings
OFF-state leakage current:
NPN: 200 µA
PNP: 10 µA
ON-state saturation voltage:
NPN: 1.25 V at 50 mA
PNP: 1.45 V at 50 mA
Vibration and Mechanical Shock
All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz
maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum
acceleration) requirements. Also meets IEC 60947-5-2 (Shock: 30G 11 ms
duration, half sine wave) requirements.
Connections
Standard Models: 2 m (6.5 ft) or 9 m (30 ft) attached PVC cable, or 150 mm
(6 in) pigtail with M8 or M12 threaded connection, depending on the model
ordered
Chemical-Resistant Models: 2 m (6.5 ft) cable encased in 3/16 in O.D. PFA
tubing
Environmental Rating
Standard Models: IEC IP67
Chemical-Resistant Models: IEC IP67 (NEMA6) and PW12 1200 psi
washdown per NEMA ICS5, Annex F-2002
Conditions
Operating Temperature: –20 °C to +55 °C (–4 °F to +131°F)
Storage Temperature: –30 °C to +75 °C (–22 °F to +167 °F)
95% at +50 °C maximum relative humidity (non-condensing)
Certifications
(Chemical-resistant models are
not UR/UL approved.)
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance with
local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
www.bannerengineering.com
.
Supply Wiring (AWG) Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Dimensions
3.5 mm
(0.14")
22 mm
(0.86")
23.1 mm
(0.91")
3.4 mm
(0.13")
5.1 mm
(0.20")
15.0 mm
(0.59")
4.7 mm
(0.19")
Polarized Retro
Models
M3 mounting
screws included
8.0 mm
(0.31")
12.4 mm
(0.49")
Ø 3 mm (0.12")
max. torque
0.9 Nm (8 in-lbf)
Emitter (opposed mode models)
Emitter (all other models)
Figure 1. Standard Models
WORLD-BEAM
®
Q12 Series Sensor
4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 119223 Rev. K
购买、咨询产品请填写询价信息:(3分钟左右您将得到回复)
询价型号*数量*批号封装品牌其它要求
删除
删除
删除
删除
删除
增加行数
  •  公司名:
  • *联系人:
  • *邮箱:
  • *电话:
  •  QQ:
  •  微信:

  • 关注官方微信

  • 联系我们
  • 电话:13714778017
  • 周一至周六:9:00-:18:00
  • 在线客服:

天天IC网由深圳市四方好讯科技有限公司独家运营

天天IC网 ( www.ttic.cc ) 版权所有©2014-2023 粤ICP备15059004号

因腾讯功能限制,可能无法唤起QQ临时会话,(点此复制QQ,添加好友),建议您使用TT在线询价。

继续唤起QQ 打开TT询价