4
LT1013
,
LT1013D
,
LT1013M
,
LT1013AM
SLOS018I –MAY 1988–REVISED JULY 2016
www.ti.com
Product Folder Links: LT1013 LT1013D LT1013M LT1013AM
Submit Documentation Feedback Copyright © 1988–2016, Texas Instruments Incorporated
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Supply voltage is V
CC+
with respect to V
CC–
.
(3) Differential voltage is IN+ with respect to IN−.
(4) The output may be shorted to either supply.
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
(1)
MIN MAX UNIT
V
CC+
– V
CC–
Supply voltage
(2)
–0.3 44 V
V
I
Input voltage (any input) V
CC–
– 5 V
CC+
V
Differential input voltage
(3)
±30 V
Duration of short-circuit current at (or below) 25°C
(4)
Unlimited
Case temperature for 60 s FK package 260 °C
Lead temperature 1,6 mm (1/16 inch)
from case for 10 s
JG package 300 °C
T
J
Operating virtual junction temperature 150 °C
T
stg
Storage temperature –65 150 °C
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
6.2 ESD Ratings
VALUE UNIT
LT1013 in D and P packages
V
(ESD)
Electrostatic
discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±1000
V
Charged-device model (CDM), per JEDEC specification JESD22-C101
(2)
±500
LT1013D in D and P packages
V
(ESD)
Electrostatic
discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±1000
V
Charged-device model (CDM), per JEDEC specification JESD22-C101
(2)
±500
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC+
– V
CC–
Supply voltage 5 30 V
T
A
Ambient temperature
LT1013C, LT1013D 0 70
°CLT1013DI –40 105
LT1013M, LT1013AM, LT1013DM –55 125
V
ICM
Input common-mode voltage
LT1013C, LT1013D, LT1013DI V
CC–
V
CC+
– 2
V
LT1013M, LT1013AM, LT1013DM V
CC-
+ 0.1 V
CC+
– 2