17. High Temperature Loading
Specified
Value
Temperature
Compensating(Class1)
Standard
Appearance : No abnormality
Capacitance change : Within ±3% or ±0.3pF, whichever is larger.
Q : C<10pF: Q≧200+10C
10≦C<30pF:Q≧275+2.5C
C≧30pF: Q≧350(C:Nominal capacitance)
Insulation resistance : 1000 MΩ min.
High Frequency Type
Appearance : No abnormality
Capacitance change : Within ±3% or ±0.3pF, whichever is larger.
Insulation resistance : 1000 MΩ min.
High Permittivity (Class2) Note 1
Appearance : No abnormality
Capacitance change : Within ±12.5% (BJ, B7, C6, C7, LD(※))
Within ±30% (F)
Dissipation factor : 5.0% max.(BJ, B7, C6, C7, LD(※))
11.0% max.(F)
Insulation resistance : 50 MΩμF or 1000 MΩ, whichever is smaller.
Note: ※LD Low distortion high value multilayer ceramic capacitor
Test
Methods and
Remarks
Class 1 Class 2
Standard High Frequency Type BJ, LD(※), F C6 B7, C7
Preconditioning None
Voltage treatment(Twice the rated voltage shall be applied for
1 hour at 85℃, 105℃ or 125℃) Note 3, 4
Temperature Maximum operating temperature Maximum operating temperature
Duration 1000+48/-0 hrs 1000+48/-0 hrs
Applied voltage Rated voltage×2 Rated voltage×2 Note 4
Charge/discharge
current
50mA max. 50mA max.
Recovery 6 to 24hr (Standard condition) Note 5 24±2 hrs (Standard condition) Note 5
Note: ※LD Low distortion high value multilayer ceramic capacitor
Note 1 The figures indicate typical specifications. Please refer to individual specifications in detail.
Note 2 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150+0/-10℃ for an hour and kept at room temperature for
24±2hours.
Note 3 Voltage treatment : Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in
the test conditions, and kept at room temperature for 24±2hours.
Note 4 150% of rated voltage is applicable to some items. Please refer to their specifications for further information.
Note 5 Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa When there are questions concerning
measurement results, in order to provide correlation data, the test shall be conducted under the following condition.
Temperature: 20±2℃, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa Unless otherwise specified, all the tests are conducted under the
"standard condition".