In the RCC register, the SYSDIV field specifies which divisor is used to generate the system clock
from either the PLL output or the oscillator source (depending on how the BYPASSbit in this register
is configured). When using the PLL, the VCO frequency of 400 MHz is predivided by 2 before the
divisor is applied. Table 6-2 shows how the SYSDIV encoding affects the system clock frequency,
depending on whether the PLL is used (BYPASS=0) or another clock source is used (BYPASS=1).
The divisor is equivalent to the SYSDIV encoding plus 1. For a list of possible clock sources, see
Table 6-1 on page 68.
Table 6-2. Possible System Clock Frequencies Using the SYSDIV Field
StellarisWare Parameter
a
Frequency (BYPASS=1)Frequency
(BYPASS=0)
DivisorSYSDIV
SYSCTL_SYSDIV_1
b
Clock source frequency/2reserved/10x0
SYSCTL_SYSDIV_2Clock source frequency/2reserved/20x1
SYSCTL_SYSDIV_3Clock source frequency/3reserved/30x2
SYSCTL_SYSDIV_4Clock source frequency/450 MHz/40x3
SYSCTL_SYSDIV_5Clock source frequency/540 MHz/50x4
SYSCTL_SYSDIV_6Clock source frequency/633.33 MHz/60x5
SYSCTL_SYSDIV_7Clock source frequency/728.57 MHz/70x6
SYSCTL_SYSDIV_8Clock source frequency/825 MHz/80x7
SYSCTL_SYSDIV_9Clock source frequency/922.22 MHz/90x8
SYSCTL_SYSDIV_10Clock source frequency/1020 MHz/100x9
SYSCTL_SYSDIV_11Clock source frequency/1118.18 MHz/110xA
SYSCTL_SYSDIV_12Clock source frequency/1216.67 MHz/120xB
SYSCTL_SYSDIV_13Clock source frequency/1315.38 MHz/130xC
SYSCTL_SYSDIV_14Clock source frequency/1414.29 MHz/140xD
SYSCTL_SYSDIV_15Clock source frequency/1513.33 MHz/150xE
SYSCTL_SYSDIV_16Clock source frequency/1612.5 MHz (default)/160xF
a. This parameter is used in functions such as SysCtlClockSet() in the Stellaris Peripheral Driver Library.
b. SYSCTL_SYSDIV_1 does not set the USESYSDIV bit. As a result, using this parameter without enabling the PLL results
in the system clock having the same frequency as the clock source.
The SYSDIV2 field in the RCC2 register is 2 bits wider than the SYSDIV field in the RCC register
so that additional larger divisors up to /64 are possible, allowing a lower system clock frequency for
improved Deep Sleep power consumption. When using the PLL, the VCO frequency of 400 MHz is
predivided by 2 before the divisor is applied. The divisor is equivalent to the SYSDIV2 encoding
plus 1. Table 6-3 shows how the SYSDIV2 encoding affects the system clock frequency, depending
on whether the PLL is used (BYPASS2=0) or another clock source is used (BYPASS2=1). For a list
of possible clock sources, see Table 6-1 on page 68.
Table 6-3. Examples of Possible System Clock Frequencies Using the SYSDIV2 Field
StellarisWare Parameter
a
Frequency (BYPASS2=1)Frequency
(BYPASS2=0)
DivisorSYSDIV2
SYSCTL_SYSDIV_1
b
Clock source frequency/2reserved/10x00
SYSCTL_SYSDIV_2Clock source frequency/2reserved/20x01
SYSCTL_SYSDIV_3Clock source frequency/3reserved/30x02
SYSCTL_SYSDIV_4Clock source frequency/450 MHz/40x03
SYSCTL_SYSDIV_5Clock source frequency/540 MHz/50x04
June 22, 201070
Texas Instruments-Production Data
System Control