Register 26: Ethernet PHY Management Register 23 – LED Configuration
(MR23), address 0x17
This register enables software to select the source that causes the LED1 and LED0 signals to toggle.
Ethernet PHY Management Register 23 – LED Configuration (MR23)
Base 0x4004.8000
Address 0x17
Type R/W, reset 0x0010
0123456789101112131415
LED0[3:0]LED1[3:0]reserved
R/WR/WR/WR/WR/WR/WR/WR/WROROROROROROROROType
0000100000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x00ROreserved15:8
LED1 Source
The LED1 field selects the source that toggles the LED1 signal.
DescriptionValue
Link OK0x0
RX or TX Activity (Default LED1)0x1
Reserved0x2
Reserved0x3
Reserved0x4
100BASE-TX mode0x5
10BASE-T mode0x6
Full-Duplex0x7
Link OK & Blink=RX or TX Activity0x8
0x1R/WLED1[3:0]7:4
LED0 Source
The LED0 field selects the source that toggles the LED0 signal.
DescriptionValue
Link OK (Default LED0)0x0
RX or TX Activity0x1
Reserved0x2
Reserved0x3
Reserved0x4
100BASE-TX mode0x5
10BASE-T mode0x6
Full-Duplex0x7
Link OK & Blink=RX or TX Activity0x8
0x0R/WLED0[3:0]3:0
457June 22, 2010
Texas Instruments-Production Data
Stellaris® LM3S8530 Microcontroller