Register 6: PWM Interrupt Enable (PWMINTEN), offset 0x014
This register controls the global interrupt generation capabilities of the PWM module. The events
that can cause an interrupt are the fault input and the individual interrupts from the PWM generators.
Note: The "n" in the INTFAULTn and INTPWMn bits in this register correspond to the PWM
generators, not to the FAULTn signals.
PWM Interrupt Enable (PWMINTEN)
PWM0 base: 0x4002.8000
Offset 0x014
Type R/W, reset 0x0000.0000
16171819202122232425262728293031
INTFAULT0INTFAULT1INTFAULT2INTFAULT3
reserved
R/WR/WR/WR/WROROROROROROROROROROROROType
0000000000000000Reset
0123456789101112131415
INTPWM0INTPWM1INTPWM2reserved
R/WR/WR/WROROROROROROROROROROROROROType
0000000000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x000ROreserved31:20
Interrupt Fault 3
DescriptionValue
An interrupt is sent to the interrupt controller when the fault
condition for PWM generator 3 is asserted.
1
The fault condition for PWM generator 3 is suppressed and not
sent to the interrupt controller.
0
0R/WINTFAULT319
Interrupt Fault 2
DescriptionValue
An interrupt is sent to the interrupt controller when the fault
condition for PWM generator 2 is asserted.
1
The fault condition for PWM generator 2 is suppressed and not
sent to the interrupt controller.
0
0R/WINTFAULT218
Interrupt Fault 1
DescriptionValue
An interrupt is sent to the interrupt controller when the fault
condition for PWM generator 1 is asserted.
1
The fault condition for PWM generator 1 is suppressed and not
sent to the interrupt controller.
0
0R/WINTFAULT117
July 24, 2012850
Texas Instruments-Production Data
Pulse Width Modulator (PWM)
OBSOLETE: TI has discontinued production of this device.