Register 7: ADC Underflow Status (ADCUSTAT), offset 0x018
This register indicates underflow conditions in the sample sequencer FIFOs. The corresponding
underflow condition is cleared by writing a 1 to the relevant bit position.
ADC Underflow Status (ADCUSTAT)
ADC0 base: 0x4003.8000
ADC1 base: 0x4003.9000
Offset 0x018
Type R/W1C, reset 0x0000.0000
16171819202122232425262728293031
reserved
ROROROROROROROROROROROROROROROROType
0000000000000000Reset
0123456789101112131415
UV0UV1UV2UV3reserved
R/W1CR/W1CR/W1CR/W1CROROROROROROROROROROROROType
0000000000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0000.000ROreserved31:4
SS3 FIFO Underflow
The valid configurations for this field are shown below. This bit is cleared
by writing a 1.
DescriptionValue
The FIFO for the Sample Sequencer has hit an underflow
condition, meaning that the FIFO is empty and a read was
requested. The problematic read does not move the FIFO
pointers, and 0s are returned.
1
The FIFO has not underflowed.0
0R/W1CUV33
SS2 FIFO Underflow
The valid configurations are the same as those for the UV3 field. This
bit is cleared by writing a 1.
0R/W1CUV22
SS1 FIFO Underflow
The valid configurations are the same as those for the UV3 field. This
bit is cleared by writing a 1.
0R/W1CUV11
SS0 FIFO Underflow
The valid configurations are the same as those for the UV3 field. This
bit is cleared by writing a 1.
0R/W1CUV00
571July 24, 2012
Texas Instruments-Production Data
Stellaris
®
LM3S6G65 Microcontroller
OBSOLETE: TI has discontinued production of this device.