Register 2: Brown-Out Reset Control (PBORCTL), offset 0x030
This register is responsible for controlling reset conditions after initial power-on reset.
Brown-Out Reset Control (PBORCTL)
Base 0x400F.E000
Offset 0x030
Type R/W, reset 0x0000.0002
16171819202122232425262728293031
reserved
ROROROROROROROROROROROROROROROROType
0000000000000000Reset
0123456789101112131415
reserved
BORIORreserved
ROR/WROROROROROROROROROROROROROROType
0100000000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0ROreserved31:2
BOR Interrupt or Reset
DescriptionValue
A Brown Out Event causes an interrupt to be generated to the
interrupt controller.
0
A Brown Out Event causes a reset of the microcontroller.1
1R/WBORIOR1
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0ROreserved0
July 24, 2012196
Texas Instruments-Production Data
System Control
OBSOLETE: TI has discontinued production of this device.