Analog-to-Digital Converter (ADC)
216 October 8, 2006
Preliminary
Register 11: ADC Sample Sequence Input Multiplexer Se lect 0 (ADCSSMUX0), offset 0x040
This register defines the analog input configuration for each sample in a sequence executed with
Sample Sequencer 0.
This register is 32-bits wide and contains information for eight possible samples.
Bit/Field Name Type Reset Description
31:29 reserved RO 0 Reserved bit s r eturn a n in dete rmina te va lue, and s hould nev er be
changed.
28 MUX7 R/W 0 The MUX7 field is used during the eighth sample of a sequence
executed with Sample Sequencer 0. It specifies which of the
analog i nput s is s ample d for the a nalog-t o-di git al con versio n. The
value set here indicates the corresponding pin, for example, a
value of 1 indicates the input is ADC1.
27:25 reserved RO 0 Reserved bit s r eturn a n in dete rmina te va lue, and s hould nev er be
changed.
24 MUX6 R/W 0 The MUX6 field is used during the seventh sample of a sequence
executed with Sample Sequencer 0 and specifies which of the
analog in puts is sampled for t he ana log-to-digital conversion.
23:21 reserved RO 0 Reserved bit s r eturn a n in dete rmina te va lue, and s hould nev er be
changed.
20 MUX5 R/W 0 The MUX5 field is used during the sixth sample of a sequence
executed with Sample Sequencer 0 and specifies which of the
analog in puts is sampled for t he ana log-to-digital conversion.
19:17 reserved RO 0 Reserved bit s r eturn a n in dete rmina te va lue, and s hould nev er be
changed.
16 MUX4 R/W 0 The MUX4 field is used during the fifth sample of a sequence
executed with Sample Sequencer 0 and specifies which of the
analog in puts is sampled for t he ana log-to-digital conversion.
15:13 reserved RO 0 Reserved bit s r eturn a n in dete rmina te va lue, and s hould nev er be
changed.
12 MUX3 R/W 0 The MUX3 field is used during the fourth sample of a sequence
executed with Sample Sequencer 0 and specifies which of the
analog in puts is sampled for t he ana log-to-digital conversion.
RO
0
ADC Sample Sequence Input Multiplexer Select 0 (ADCSSMUX0)
Offset 0x040
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reset
Type
000000000000000
RO RO R/W RO RO RO R/W RO RO RO R/W RO R0 RO R/W
RO
0
Reset
Type
000000000000000
RO RO R/W RO RO RO R/W RO RO RO R/W RO R0 RO R/W
MUX7
MUX6
MUX5
MUX4
MUX3
MUX2
MUX1
MUX0
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved