SLOS068P − JUNE 1976 − REVISED SEPTEMBER 2004
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
CC
= 5 V (unless otherwise noted)
LM2904
A
MIN TYP
§
MAX
25°C 3 7
V
CC
= 5 V to MAX
Non-A devices
Full range 10
V
IO
Input offset voltage
IC
ICR(min)
25°C 1 2
mV
A-suffix devices
Full range 4
a
V
IO
Average temperature coefficient
of input offset voltage
Full range 7 µV/°C
25°C 2 50
Non-V device
Full range 300
I
IO
Input offset current V
O
= 1.4 V
25°C 2 50
nA
V-suffix device
Full range 150
a
I
IO
Average temperature coefficient
of input offset current
Full range 10 pA/°C
25°C −20 −250
I
IB
Input bias current V
O
= 1.4 V
Full range −500
nA
Common-mode input voltage
25°C
0 to
V
CC
− 1.5
V
ICR
Common-mode input voltage
range
V
CC
= 5 V to MAX
Full range
0 to
V
CC
− 2
V
R
L
≥ 10 kΩ 25°C V
CC
− 1.5
R
L
= 2 kΩ Full range 22
V
High-level output voltage
Non-V device
R
L
≥ 10 kΩ Full range 23 24
V
High-level output voltage
R
L
= 2 kΩ Full range 26
V-suffix device
R
L
≥ 10 kΩ Full range 27 28
V
OL
Low-level output voltage R
L
≤ 10 kΩ Full range 5 20 mV
Large-signal differential
V
CC
= 15 V, V
O
= 1 V to 11 V,
25°C 25 100
A
VD
Large-signal differential
voltage amplification
V
CC
= 15 V, V
O
= 1 V to 11 V,
R
L
≥ 2 kΩ
Full range 15
V/mV
Common-mode rejection ratio
Non-V device 25°C 50 80
CMRR Common-mode rejection ratio
V
IC
= V
ICR(min)
V-suffix device 25°C 65 80
dB
k
SVR
Supply-voltage rejection ratio
(∆V
DD
/∆V
IO
)
V
CC
= 5 V to MAX 25°C 65 100 dB
V
O1
/V
O2
Crosstalk attenuation f = 1 kHz to 20 kHz 25°C 120 dB
25°C −20 −30 mA
V
ID
= 1 V, V
O
= 0
Source
Full range −10 mA
V
CC
= 15 V,
25°C 10 20 mA
I
O
Output current
ID
V
O
= 15 V
Sink
Full range 5 mA
Non-V device 25°C 30
V
O
= 200 mV
V-suffix device 25°C 12 40
µA
I
OS
Short-circuit output current V
CC
at 5 V, GND at −5 V, V
O
= 0 25°C ±40 ±60 mA
Supply current (two amplifiers)
V
O
= 2.5 V, No load Full range 0.7 1.2
CC
Supply current (two amplifiers)
V
CC
= MAX, V
O
= 0.5 V, No load Full range 1 2
†
All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX V
CC
for
testing purposes is 26 V for the LM2904, 32 V for the LM2904V, and 30 V for others.
‡
Full range is −55°C to 125°C for LM158, −25°C to 85°C for LM258, 0°C to 70°C for LM358, and −40°C to 125°C for LM2904.
§
All typical values are at T
A
= 25°C.