25. Loading under damp heat
Specified Value
CAL45 Type △L/L : Within ±10%
LHL□□□
Appearance : No abnormality
Inductance change : Within ±10%
Q change : Within ±30% (LHLP : only △L/L)
FBA/FBR
Test Methods and
Remarks
CAL45 Type :
Temperature : 40±2℃
Humidity : 90~95%RH
Duration : 1000 hrs
Applied current : Rated current
Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
LHL□□□ :
Temperature : 40±2℃
Humidity : 90~95%RH
Duration : 1000+48/-0 hrs
Applied current : Rated current
Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
26. Loading at high temperature
Specified Value
CAL45 Type △L/L : Within ±10%
LHL□□□
FBA/FBR
Test Methods and
Remarks
CAL45 Type :
Temperature : 85±2℃
Duration : 1000 hrs
Applied current : Rated current
Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
27. Low temperature life test
Specified Value
CAL45 Type △L/L : Within ±10%
LHL□□□
Appearance : No abnormality
Inductance change : Within ±10%
Q change : Within ±30% (LHLP : only △L/L)
FBA/FBR
Test Methods and
Remarks
CAL45 Type :
Temperature : -25±2℃
Duration : 1000 hrs
Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
LHL□□□ :
Temperature :-40±3℃
Duration : 1000+48/-0 hrs
Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
28. High temperature life test
Specified Value
CAL45 Type
LHL□□□
Appearance : No abnormality
Inductance change : Within ±10%
Q change : Within ±30% (LHLP : only △L/L)
FBA/FBR
Test Methods and
Remarks
LHL□□□ :
Temperature : 105±2℃
Duration : 1000+48/-0 hrs
Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.