▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
i_leaded_reli_e-E02R01
16. DC bias characteristic
Specified Value
CAL45 Type △L/L : Within -10%
LHL□□□
FBA/FBR
Test Methods and
Remarks
CAL45 Type : Measure inductance with application of rated current using LCR meter to compare it with the initial value.
17. Body strength
Specified Value
CAL45 Type No abnormality as damage.
LHL□□□
FBA/FBR No abnormality such as cracks on body.
Test Methods and
Remarks
CAL45 Type :
Applied force :50N
Duration : 10 sec.
Speed : Shall attain to specified force in 2 sec.
FBA :
Applied force : 50±3N
Duration : 30±1 sec.
18. Resistance to vibration
Specified Value
CAL45 Type △L/L : Within ±5%
LHL□□□
Appearance : No abnormality
△L/L : Within ±5%
Q change : Within ±30% (LHLP : only △L/L)
FBA/FBR
Appearance : No abnormality
Impedance change : Within ±20%
Test Methods and
Remarks
CAL45 Type :
Directions : 2 hrs each in X, Y and Z directions total : 6hrs.
Frequency range : 10 to 55 to 10Hz (1min.)
Amplitude : 1.5mm
Mounting method : Soldering onto printed board.
Recovery : At least 1hr of recovery under the standard condition after the test, followed by the measurement within 2hrs.
LHL□□□・FBA/FBR :
Directions : 2 hrs each in X, Y and Z directions total : 6hrs.
Frequency range : 10 to 55 to 10Hz (1min.)
Amplitude : 1.5mm
Mounting method : Soldering onto printed board.
19. Resistance to shock
Specified Value
CAL45 Type No significant abnormality in appearance
LHL□□□
FBA/FBR
Test Methods and
Remarks
CAL45 Type :
Drop test
Impact material : concrete or vinyl tile
Height : 1m
Total number of drops : 10 times