SCLS467B − FEBRUAR Y 2003 − REVISED MAY 2004
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS
V
CC
MIN TYP MAX UNIT
I
OH
= −50 µA 2 V to 5.5 V V
CC
−0.1
I
OH
= −2 mA 2.3 V 2
V
OH
I
OH
= −6 mA 3 V 2.48
V
I
OH
= −12 mA 4.5 V 3.8
I
OL
= 50 µA 2 V to 5.5 V 0.1
I
OL
= 2 mA 2.3 V 0.4
V
OL
I
OL
= 6 mA 3 V 0.44
V
I
OL
= 12 mA 4.5 V 0.55
R
ext
/C
ext
†
V
I
= 5.5 V or GND 2 V to 5.5 V ±2.5
I
0 ±1
µA
A, B, and CLR
V
I
= 5.5 V or GND
0 to 5.5 V ±1
I
CC
Quiescent V
I
= V
CC
or GND, I
O
= 0 5.5 V 20 µA
3 V 280
I
Active state
V
I
= V
CC
or GND,
4.5 V 650
µA
5.5 V 975
I
off
V
I
or V
O
= 0 to 5.5 V 0 5 µA
3.3 V 1.9
C
i
V
I
= V
CC
or GND
5 V 1.9
pF
†
This test is performed with the terminal in the off-state condition.
timing requirements over recommended operating free-air temperature range, V
CC
= 3.3 V ± 0.3 V
(unless otherwise noted) (see Figure 1)
T
A
= 25°C
MIN TYP MAX
CLR 5 5
t
w
duration
A
or B trigger 5 5
ns
C
ext
= 100 pF
‡
76
‡
ns
t
rr
R
ext
= 1 kΩ
C
ext
= 0.01 µF
‡
1.8
‡
µs
‡
See retriggering data in the application information section.
timing requirements over recommended operating free-air temperature range, V
CC
= 5 V ± 0.5 V
(unless otherwise noted) (see Figure 1)
T
A
= 25°C
MIN TYP MAX
CLR 5 5
t
w
duration
A
or B trigger 5 5
ns
C
ext
= 100 pF
‡
59
‡
ns
t
rr
R
ext
= 1 kΩ
C
ext
= 0.01 µF
‡
1.5
‡
µs
‡
See retriggering data in the application information section.