For the latest product information, Please visit our website at
http://www.ece.com.tw
and You Always Relax!
AUTOMOTIVE RELAY
ETR CAR SERIES
▓ FEATURES
European and American footprints offer different market selections.
Washable type, flux-proofed type, unclosed type available for different customer’s
requirement.
FE130 material applied to strengthen the contact in order to carry the high current load.
Comply with RoHS, REACH and ELV regulations.
▓ SPECIFICATIONS
Contact Resistance Max. 100mΩ at initial value. @1A,6VDC
Contact Capacity
D/DM: 40A at 12VDC L/R=0
L/LM: 30A at 12VDC L/R=0
Operate Time 10m Sec. Max.
Release Time 10m Sec. Max.
Dielectric Strength
Between coil & Contact: 1200VAC at 50/60Hz for one minute
Between Contacts: 750VAC at 50/60Hz for one minute
Insulation Resistance
100MΩ Min. at 500VDC
▓ COIL SPECIFICATION AT 20℃
℃℃
℃
Coil
Sensitivity
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil
Resistance
(Ω±10%)
Power
Consumption
(W)
Pull-In
Voltage
(VDC)
Drop-Out
Voltage
(VDC)
Max.
Allowable
Voltage
(VDC)
6 315.7 19 Abt. 1.89
12 133.3 90
24 66.2 362
36 44 816
CAR-D
48 33 1450
Abt. 1.59
70%
Max.
5%
Min.
160%
6 100 60
12 50 240
24 25 960
36 16.7 2160
CAR-L
48 12.5 3840
Abt. 0.6
75%
Max.
10%
Min.
160%