© 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCS-18/CS-18 Page 5
CCS-18\CS-18\072013\Q3
Series CCS-18/CS-18
High Power Multi-Throw DC–12 GHz
Normally Open Coaxial Switch
COAX SWITCHES
TRUTH TABLE Normally Open
CCS -18 N X4C -TD
Logic Input RF Path Indicator
Switches
123 J1J2J3J4 EFGH
000
On Off Off Off C 000
100 Off
On Off Off 0 C 00
010 OffOff
On Off 0 0 C 0
1 1 0 Off Off Off
On 000C
1 1 1 Off Off Off Off 0 0 0 0
TRUTH TABLE Normally Open
CCS -18N X3C-TD
Logic
Input
RF Path Indicator
Switches
12 J1J2J3 EFG
00
On Off Off C 00
10 Off
On Off 0 C 0
01 OffOff
On 00C
1 1 Off Off Of f 0 0 0
TRUTH TABLE Normally Open
CCS -18N X3C-T
Logic
Input
RF Path Indicator
Switches
123 J1J2J3 EFG
100
On Off Off C 00
010 Off
On Off 0 C 0
001 OffOff
On 00C
TRUTH TABLE Normally Open
CCS -18 N X4C -T
Logic Input RF Path Indicator
Switches
1234 J1J2J3J4 EFGH
1000
On Off Off Of f C 000
0100 Off
On Off Off 0 C 00
0010 OffOff
On Off 0 0 C 0
0001 OffOffOff
On 000C