Philips Semiconductors Product specification
74ALVT16260
2.5V/3.3V 12-bit to 24-bit multiplexed D-type latches
(3-State)
1998 Jan 30
6
DC ELECTRICAL CHARACTERISTICS (3.3V 0.3V RANGE)
LIMITS
SYMBOL PARAMETER TEST CONDITIONS Temp = -40°C to +85°C UNIT
MIN TYP
1
MAX
V
IK
Input clamp voltage V
CC
= 3.0V ; I
IK
= –18mA –0.85
1.2
V
p
V
CC
= 3.0 to 3.6V ; I
OH
= –100µA V
CC–
0.2 V
CC
OH
-
V
CC
= 3.0V ; I
OH
= –32mA 2.0 2.3
V
CC
= 3.0V ; I
OL
= 100µA 0.07 0.2
p
V
CC
= 3.0V ; I
OL
= 16mA 0.25 0.4
OL
–
V
CC
= 3.0V ; I
OL
= 32mA 0.3 0.5
V
CC
= 3.0V ; I
OL
= 64mA 0.4 0.55
V
RST
Power-up output low voltage
6
V
CC
= 3.6V ; I
O
= 1mA; V
I
= V
CC
or GND 0.55 V
V
CC
= 3.6V ; V
I
= V
CC
or GND Control pins 0.1 ±1
p
V
CC
= 0 or 3.6V ; V
I
= 5.5V 0.1 10
I
V
CC
= 3.6V ; V
I
= V
CC
p
0.1 1
V
CC
= 3.6V ; V
I
= 0V
0.1 -5
I
OFF
Off current V
CC
= 0V ; V
I
or V
O
= 0 to 4.5V 0.1 ±100 µA
V
CC
= 3V ; V
I
= 0.8V 75 130
I
HOLD
p
V
CC
= 3V ; V
I
= 2.0V –75 –140
µA
V
CC
= 0V to 3.6V ; V
CC
= 3.6V ±500
I
EX
Current into an output in the
High state when V
O
> V
CC
V
O
= 5.5V ; V
CC
= 3.0V 10 125 µA
I
PU/PD
Power up/down 3-State output
current
3
V
CC
≤ 1.2V ; V
O
= 0.5V to V
CC
; V
I
= GND or V
CC
OE/OE = Don’t care
1 ±100 µA
I
OZH
3-State output High current V
CC
= 3.6V ; V
O
= 3.0V ; V
I
= V
IL
or V
IH
0.5 5 µA
I
OZL
3-State output Low current V
CC
= 3.6V ; V
O
= 0.5V ; V
I
= V
IL
or V
IH
0.5 5 µA
I
CCH
V
CC
= 3.6V ; Outputs High, V
I
= GND or V
CC,
I
O
=
0 0.04 0.1
I
CCL
Quiescent supply current V
CC
= 3.6V ; Outputs Low, V
I
= GND or V
CC,
I
O
=
0 3.7 6 mA
I
CCZ
V
CC
= 3.6V ; Outputs Disabled; V
I
= GND or V
CC,
I
O
= 0
5
0.04 0.1
∆I
CC
Additional supply current per
input pin
2
V
CC
= 3V to 3.6V ; One input at V
CC
–0.6V,
Other inputs at V
CC
or GND
0.04 0.4 mA
NOTES:
1. All typical values are at V
CC
= 3.3V and T
amb
= 25°C.
2. This is the increase in supply current for each input at the specified voltage level other than V
CC
or GND
3. This parameter is valid for any V
CC
between 0V and 1.2V with a transition time of up to 10msec. From V
CC
= 1.2V to V
CC
= 3.3V ± 0.2V a
transition time of 100µsec is permitted. This parameter is valid for T
amb
= 25°C only.
4. Unused pins at V
CC
or GND.
5. I
CCZ
is measured with outputs pulled up to V
CC
or pulled down to ground.
6. For valid test results, data must not be loaded into the flip-flops (or latches) after applying power.
7. This is the bus hold overdrive current required to force the input to the opposite logic state.