185
AM5706, AM5708
www.ti.com
SPRS961B –AUGUST 2016–REVISED SEPTEMBER 2017
Submit Documentation Feedback
Product Folder Links: AM5706 AM5708
SpecificationsCopyright © 2016–2017, Texas Instruments Incorporated
Table 5-42. Virtual Functions Mapping for DSS VOUT3 (continued)
BALL BALL NAME Delay Mode Value MUXMODE
DSS_VIRTUAL1 3
B1 gpmc_ad6 14 vout3_d6
E1 gpmc_ad2 14 vout3_d2
C1 gpmc_ad3 14 vout3_d3
K1 gpmc_a7 15 vout3_d23
L1 gpmc_a3 15 vout3_d19
A2 gpmc_ad10 14 vout3_d10
B2 gpmc_ad7 14 vout3_d7
J2 gpmc_a10 15 vout3_de
K2 gpmc_a5 15 vout3_d21
C2 gpmc_ad8 14 vout3_d8
D2 gpmc_ad5 14 vout3_d5
M1 gpmc_a0 15 vout3_d16
C3 gpmc_ad12 14 vout3_d12
L3 gpmc_a11 15 vout3_fld
D3 gpmc_ad9 14 vout3_d9
NOTE
To configure the desired Manual IO Timing Mode the user must follow the steps described in
section "Manual IO Timing Modes" of the Device TRM.
The associated registers to configure are listed in the CFG REGISTER column. For more
information please see the Control Module Chapter in the Device TRM.
Manual IO Timings Modes must be used to guaranteed some IO timings for VOUT2. See Table 5-29
Modes Summary for a list of IO timings requiring the use of Manual IO Timings Modes. See Table 5-43
Manual Functions Mapping for DSS VOUT2 IOSET1 for a definition of the Manual modes.
Table 5-43 lists the A_DELAY and G_DELAY values needed to calculate the correct values to be set in
the CFG_x registers.