Series AM30E-Z
30Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R12.D 3 of 4 North America only
Safety Specifications
Parameters
Agency Approvals CE
Standards
EN55022 Class A
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria A (external 220uF/100V cap required)
IEC61000-4-5, Perf. Criteria A (external 220uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
NOTE: also designed to meet IEC/EN 60950-1
Pin Out Specifications
Pin
Single Dual
1 + V Input + V Input
2 - V Input - V Input
3 On/Off Control On/Off Control
4 + V Output + V Output
5 -V Output Common
6 Trim - V Output
Dimensions
1
2
3
2.54
(0.10)
5.08
(0.20)
10.16
(0.40)
50.80
(2.00)
25.40
(1.00)
Bottom View
2.54
(0.10)
2.54
(0.10)
10.16
(0.40)
10.16
(0.40)
10.16
(0.40)
5.08
(0.20)
Single and Dual Output Models
5.08
(0.20)
4
5
6
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.35 (±0.014)
Case Tolerance ±0.50 (±0.02)
Diameter 1.00
(0.04)