Series AM100HB-UZ
100 Watt | Half Brick DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 054e R3.D 1 of 4 North America only
FEATURES:
• RoHS compliant • Regulated output
• Wide 2:1 Input range • High efficiency
• Very low ripple and noise • Operating temperature range: -40 to +85ºC
• On/Off Control and Trim Function • 1500VDC I/O Isolation
Models
Single output
Model Input Voltage (V)
Output Voltage
(V)
Output Current max (A) Input Filter
AM100HB-2403S-UZ 18-36 3.3 20 type
AM100HB-2405S-UZ 18-36 5 20 type
AM100HB-2412S-UZ 18-36 12 8.3 L type
AM100HB-2415S-UZ 18-36 15 6.7 L type
AM100HB-2424S-UZ 18-36 24 4.2 L type
AM100HB-2428S-UZ 18-36 28 3.6 L type
AM100HB-2448S-UZ 18-36 48 2.1 L type
AM100HB-4803S-UZ 36-72 3.3 20 type
AM100HB-4805S-UZ 36-72 5 20 type
AM100HB-4812S-UZ 36-72 12 8.3 L type
AM100HB-4815S-UZ 36-72 15 6.7 L type
AM100HB-4824S-UZ 36-72 24 4.2 L type
AM100HB-4848S-UZ 36-72 48 2.1 L type
AM100HB-11005S-UZ 66-160 5 20 type
AM100HB-11012S-UZ 66-160 12 8.3 L type
AM100HB-11015S-UZ 66-160 15 6.7 L type
AM100HB-11024S-UZ 66-160 24 4.2 L type
AM100HB-11048S-UZ 66-160 48 2.1 L type
NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated
output load unless otherwise specified.
Input Specifications
Parameters Nominal Typical Maximum Units
Voltage range
24
48
110
18-36
36-72
66-160
VDC
Remote Control
CNTRL open or connect to +Vin
CNTRL connect to –Vin
On
Off
Logic Low 0.4 V
Turn On Time 10 ms
Start-up Delay Time 150 ms
Isolation Specifications
Parameters Conditions Typical Maximum Units
Tested I/O voltage 1 Min 1500 VDC
Tested Input / Case Ivoltage 1 Min 500 VDC
Tested Output / Case voltage 1 Min 500 VDC
Output Specifications
Parameters Conditions Typical Maximum Units
Set point accuracy ±1 %
Trim range ±10 %
Dynamic Response 200µs setting time 50-75% & 50-25% load 3% of Vout Pk deviation
Short Circuit protection Continuous
Short Circuit restart Auto recovery
Over Temperature Protection >105 110 115
o
C