Rev.1 Page 9
DC Characteristics :
(T
a
= 0 to 70°C, V
CC
= +3.3V %, V
SS
= 0V)
Notes:
1. I
CC
is specified as an average current. It depends on output loading condition and cycle rate when the
device is selected. I
CC
max is specified at the output open condition.
2. Address can be changed once or less while RAS = V
IL
.
3. For I
CC4
, address can be changed once or less within one EDO page mode cycle time.
Parameter Symbol Test Conditions
AD404M42V Unit Notes
-5 -6
Min Max Min Max
Input leakage current I
LI
+ 0.3V
-5 5 -5 5
Output leakage current I
LO
+ 0.3V
Dout = Disable
-5 5 -5 5
Output high Voltage V
OH
I
OH
= -2mA 2.4 - 2.4 - V
Output low voltage V
OL
I
OL
= +2mA - 0.4 - 0.4 V
CC
CC