3
ACA2407E
Data Sheet
204205B • Skyworks Proprietary and Condential Information • Products and Product Information are Subject to Change Without Notice • September 19, 2016
Table 2: Absolute Mimimum and Maximum Ratings
ELECTRICAL CHARACTERISTICS
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure to
absolute ratings for extended periods of time may adversely affect reliability.
Table 3: Operating Ranges
Notes:
(1) Pins 2, 4, 5 and 7 should be AC-coupled. No external DC bias should be
applied.
(2) Pin 6 should be AC-grounded and/or pulled to ground through a resistor for
current control.
(3)Pins11and14arebiasfeedsforinputampliers1Aand1B.Noexternal
DC bias should be applied.
(4) Pins 10 and 15 receive DC bias directly from pins 11 and 14.
The device may be operated safely over these conditions; however, parametric
performance is guaranteed only over the conditions defined in the electrical
specications.
PARAMETER
MIN MAX
UNIT
Supply (pins 12, 13) 0 +28 VDC
RF Power at Inputs (pins 4, 5) - +75 dBmV
Storage Temperature -65 +150 °C
Soldering Temperature - +260 °C
Soldering Time - 5.0 Sec
PARAMETER MIN TYP MAX UNIT
Supply: V
DD
(pins 12, 13)-+24- VDC
Voltage at I
SET
(pin 6) -+3-VDC
RF Frequency40-1000MHz
Case Te mperature-40 -+11
C