Surface-Mount Ceramic Multilayer Capacitors
Capacitance shall be measured by the steps shown in the
following table.
The capacitance change should be measured after 5 min at
each specified temperature stage.
(1) Class I
Temperature Coefficient shall be calculated from the formula
as below
Temp, Coefficient =
[ppm/℃]
C1: Capacitance at step c
C2: Capacitance at 125℃
∆T: 100℃(=125℃-25℃)
(2) Class II
Capacitance Change shall be calculated from the formula as
below
∆C =
x 100%
C1: Capacitance at step c
C2: Capacitance at step b or d
<General purpose series>
Class1:
∆ C/C: ± 30ppm
Class2:
X7R: ∆ C/C: ±15%
<High Capacitance series>
Class2:
X7R/X5R: ∆ C/C: ±15%
High
Temperature
Exposure
Unpowered ; 1000hours @ T=150℃
Measurement at 24± 2 hours after test conclusion.
No visual damage
Δ C/C:
Class1:
NP0: within ± 0.5% or 0.5 pF
whichever is greater
Class2:
X7R: ± 10%
D.F.:
within initial specified value
IR: