13.6 RELIABILITY
Test Conditions
Test Item
Normal Temp. type Extended Temp. type
Note
High Temperature Operation
50
±
3
°
C , t=96 hrs 70
±
3
°
C , t=96 hrs
Low Temperature Operation
0
±
3
°
C , t=96 hrs -20
±
3
°
C , t=96 hrs
High Temperature Storage
70
±
3
°
C , t=96 hrs 80
±
3
°
C , t=96 hrs
1,2
Low Temperature Storage
-20
±
3
°
C , t=96 hrs -30
±
3
°
C , t=96 hrs
1,2
Temperature Cycle
-20
°
C ~ 25
°
C ~ 70
°
C
30 m in. 5 min. 30 min.
( 1 cycle )
Total 5 cycle
-30
°
C ~ 25
°
C ~ 80
°
C
30 min. 5 min. 30 min.
( 1 cycle )
Total 5 cycle
1,2
Humidity Test
40
°
C, Humidity 90%, 96 hrs
1,2
Vibration Test (Packing)
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
2
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
Current drain should be smaller than the specific value.
Function of the module should be maintained.
Appearance and display quality should not have degraded noticeably.
Contrast ratio should be greater than 50% of the initial value.
Date : 2001/12/12 AMPIRE CO., LTD.
17