SmartFusion DC and Switching Characteristics
2-2 Revision 10
Table 2-2 • Analog Maximum Ratings
Parameter Conditions Min. Max. Units
ABPS[n] pad voltage (relative to ground) GDEC[1:0] = 00 (±15.36 V range)
Absolute maximum –11.5 14.4 V
Recommended –11 14 V
GDEC[1:0] = 01 (±10.24 V range) –11.5 12 V
GDEC[1:0] = 10 (±5.12 V range) –6 6 V
GDEC[1:0] = 11 (±2.56 V range) –3 3 V
CM[n] pad voltage relative to ground) CMB_DI_ON = 0 (ADC isolated)
COMP_EN = 0 (comparator off, for the
associated even-numbered comparator)
Absolute maximum –0.3 14.4 V
Recommended –0.3 14 V
CMB_DI_ON = 0 (ADC isolated)
COMP_EN = 1 (comparator on)
–0.3 3 V
TMB_DI_ON = 1 (direct ADC in) –0.3 3 V
TM[n] pad voltage (relative to ground) TMB_DI_ON = 0 (ADC isolated)
COMP_EN = 1(comparator on)
–0.3 3 V
TMB_DI_ON = 1 (direct ADC in) –0.3 3 V
ADC[n] pad voltage (relative to ground) –0.3 3.6 V