1-188
5V Operating Conditions
Absolute Maximum Ratings
1
Free air temperature range
Recommended Operating Conditions
Electrical Specifications
Symbol Parameter Limits Units
V
CC
DC Supply Voltage –0.5 to +7.0 V
V
I
Input Voltage –0.5 to V
CC
+0.5 V
V
O
Output Voltage –0.5 to V
CC
+0.5 V
I
IO
I/O Source Sink
Current
2
±20 mA
T
STG
Storage Temperature –65 to +150 °C
Notes:
1. Stresses beyond those listed under “Absolute Maximum Ratings”
may cause permanent damage to the device. Exposure to
absolute maximum rated conditions for extended periods may
affect device reliability. Device should not be operated outside
the Recommended Operating Conditions.
2. Device inputs are normally high impedance and draw
extremely low current. However, when input voltage is greater
than V
CC
+ 0.5 V or less than GND – 0.5 V, the internal protection
diodes will forward bias and can draw excessive current.
Parameter Commercial Industrial Military Units
Temperature
Range
1
0 to +70 –40 to +85 –55 to
+125
°C
5V Power
Supply
Tolerance
±5 ±10 ±10 %V
CC
Note:
1. Ambient temperature (T
A
) is used for commercial and
industrial; case temperature (T
C
) is used for military.
Symbol Parameter Test Condition
Commercial Industrial Military
UnitsMin. Max. Min. Max. Min. Max.
V
OH
1,2
HIGH Level Output I
OH
= –4 mA (CMOS) 3.7 3.7 V
I
OH
= –6 mA (CMOS) 3.84 V
I
OH
= –10 mA (TTL)
3
2.40 V
V
OL
1,2
LOW Level Output I
OL
= +6 mA (CMOS) 0.33 0.4 0.4 V
I
OL
= +12 mA (TTL)
3
0.50 V
V
IH
HIGH Level Input TTL Inputs 2.0 V
CC
+ 0.3 2.0 V
CC
+ 0.3 2.0 V
CC
+ 0.3 V
V
IL
LOW Level Input TTL Inputs –0.3 0.8 –0.3 0.8 –0.3 0.8 V
I
IN
Input Leakage V
I
= V
CC
or GND –10 +10 –10 +10 –10 +10 µA
I
OZ
3-state Output Leakage V
O
= V
CC
or GND –10 +10 –10 +10 –10 +10 µA
C
IO
I/O Capacitance
3,4
10 10 10 pF
I
CC(S)
Standby V
CC
Supply Current (typical = 0.7 mA) 2 10 20 mA
I
CC(D)
Dynamic V
CC
Supply Current See “Power Dissipation” Section
Notes:
1. Actel devices can drive and receive either CMOS or TTL signal levels. No assignment of I/Os as TTL or CMOS is required.
2. Tested one output at a time, V
CC
= min.
3. Not tested, for information only.
4. V
OUT
= 0V, f = 1 MHz.
5. Typical standby current = 0.7 mA. All outputs unloaded. All inputs = V
CC