Continuous-Time Switch Family
A1 101, A1102, A1 103,
A1104, and A1106
4
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
MAGNETIC OPERATING CHARACTERISTICS
1
over full operating voltage and ambient temperature ranges, unless otherwise noted
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Operate Point B
OP
A1101
T
A
= 25°C 50 100 160 G
Operating Temperature Range 30 100 175 G
A1102
T
A
= 25°C 130 180 230 G
Operating Temperature Range 115 180 245 G
A1103
T
A
= 25°C 220 280 340 G
Operating Temperature Range 205 280 355 G
A1104
T
A
= 25°C 70 – 350 G
Operating Temperature Range 35 – 450 G
A1106
T
A
= 25°C 280 340 400 G
Operating Temperature Range 260 340 430 G
Release Point B
RP
A1101
T
A
= 25°C 10 45 130 G
Operating Temperature Range 10 45 145 G
A1102
T
A
= 25°C 75 125 175 G
Operating Temperature Range 60 125 190 G
A1103
T
A
= 25°C 165 225 285 G
Operating Temperature Range 150 225 300 G
A1104
T
A
= 25°C 50 – 330 G
Operating Temperature Range 25 – 430 G
A1106
T
A
= 25°C 180 240 300 G
Operating Temperature Range 160 240 330 G
Hysteresis B
HYS
A1101
T
A
= 25°C 20 55 80 G
Operating Temperature Range 20 55 80 G
A1102
T
A
= 25°C 30 55 80 G
Operating Temperature Range 30 55 80 G
A1103
T
A
= 25°C 30 55 80 G
Operating Temperature Range 30 55 80 G
A1104
T
A
= 25°C 20 55 – G
Operating Temperature Range 20 55 – G
A1106
T
A
= 25°C 70 105 140 G
Operating Temperature Range 70 105 140 G
1
Magnetic flux density, B, is indicated as a negative value for north-polarity magnetic fields, and as a positive value for south-polarity magnetic fields.
This so-called algebraic convention supports arithmetic comparison of north and south polarity values, where the relative strength of the field is indicated
by the absolute value of B, and the sign indicates the polarity of the field (for example, a –100 G field and a 100 G field have equivalent strength, but
opposite polarity).