Twinax • 24 AWG Stranded (19x36) .024″ Silver-coated High-Strength Copper Alloy Conductor • SCHSCA Braid Shield (93% Coverage)
TFE Teflon
®
Insulation • Blue PFA Jacket (Color Code: White, Blue)
200°C 81553 — 500
†
152.4 9.0 4.1 24 AWG .084 2.13 SCHSCA .129 3.28 77 70% 24.0 78.7
1000
†
304.8 16.0 7.3 (19x36) 93% Shield
.024″ Coverage
SCHSCA 7.3Ω/M′
24.0Ω/M′ 24.0Ω/km
78.7Ω/km
M17/176-00002
Twinax • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductor • Tinned Copper Braid Shield (85% Coverage)
Polyethylene Insulation • Black Non-contaminating PVC Jacket (One conductor has bare strand for ID)
85°C 9859 — 1000 304.8 33.0 15.0 20 AWG .158 4.01 TC Braid .235 5.97 78 66% 19.7 64.6
(7x28) 85% Shield
.038″ Coverage
TC 5.3Ω/M′
9.5Ω/M′ 17.4Ω/km
31.2Ω/km
M17/45-RG108
DCR = DC Resistance • PFA = Perfluoroalkoxy • SCHSCA = Silver-coated High-strength Copper Alloy • TC = Tinned Copper • TFE = Tetra Fluoroethylene
Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1.
†
Spools may contain more than one piece. Minimum length of any one piece is 50 ft. Length may vary ±10% from length shown for spools or reels and ±5% UnReel
®
cartons.
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
COAXIAL CABLES
6.81
6 • Coaxial Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
MIL-C-17G QPL Cable
Twinax
1 1.2 3.9
10 4.0 13.1
50 9.2 30.2
100 13.0 42.7
200 18.4 60.4
400 26.1 85.6
700 34.6 113.5
900 39.3 128.9
1000 41.4 135.8
1 .7 2.3
10 2.3 7.5
50 5.2 17.1
100 7.5 24.6
200 11.0 36.1
400 16.0 52.5
Teflon is a DuPont trademark.
Shielding
Materials
Nom. DCR
Nom.
Imp.
(Ω)
Nominal
Core OD
Nominal OD
Inch mm Inch mm
Conductor
(stranding)
Diameter
Nom. DCR
Standard
Unit Weight
Standard Lengths
Lbs. kgFt. m
UL NEC/
C(UL) CEC
Type
Part
No.
MHz
dB/
100 Ft.
dB/
100m
Nominal
Attenuation
Nominal
Capacitance
pF/mpF/Ft.
Nom.
Vel.
of
Prop.
Description