144
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
ED Series
ED Series
Medium Performance Compact EMI Power Inlet Filter
UL Recognized
CSA Certified
VDE Approved*
• Two element circuit provides medium attenuation
• Available with an internal ground-circuit inductor
(C versions) to isolate equipment chassis from
power line ground at radio frequencies
• Versions up to 15A*
• Similar to EEJ Series with alternative termination
options
• See the EC Series for better differential mode
performance
Ordering Information
3 ED 1 C
Ground Circuit Inductor
Omit if none
Output Styles
1 – .250 [6.3] spade terminals
(back)
2 – .250 [6.3] spade terminals
(bottom)
4 – Wire leads (bottom)
8 – Wire leads (back)
ED Series
Current Rating
1, 3, 6, 10 or 15A
ED1 / ED1C
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz: .22 mA
@250 VAC 50 Hz: .38 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max.): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 1 to 15A*
Operating Ambient Temperature Range
(at rated current I
r
): -10°C to +40°C
In an ambient temperature (T
a
) higher than +40°C
the maximum operating current (I
o
) is calculate
d as
follows: I
o
= I
r
(85-Ta)/45
Specifications
Available Part Numbers
1ED1 1ED2 1ED4 1ED8
3ED1 3ED2 3ED4 3ED8
6ED1 6ED2 6ED4 6ED8
10ED1
15ED1 15ED8
Ground Circuit Inductor Versions
6ED1C 6ED4C 6ED8C
10ED1C
Electrical Schematic
1
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
EC8 / ED8C
ED2
EC4 / ED4C
Note 1: C versions only