• 当前位置:
  • 首页
  • >
  • PDF资料
  • >
  • 53230A PDF文件及第7页内容在线浏览

53230A

53230A首页预览图
型号: 53230A
PDF文件:
  • 53230A PDF文件
  • 53230A PDF在线浏览
功能描述: RF/Universal Frequency Counter/Timers
PDF文件大小: 1474.82 Kbytes
PDF页数: 共24页
制造商: KEYSIGHT[Keysight Technologies]
制造商LOGO: KEYSIGHT[Keysight Technologies] LOGO
制造商网址: http://www.keysight.com
捡单宝53230A
PDF页面索引
120%
53210A 53220A 53230A
6 GHz (Option 106) 15 GHz (Option 115)
Pulse/burst frequency and pulse envelope detector (Option 150)
12
Pulse/burst measurements N/A N/A Carrier frequency, carrier period, pulse repetition interval (PRI), pulse
repetition frequency (PRF), positive and negative width
Pulse/burst width
for carrier frequency
measurements
10
N/A N/A > 200 ns
Narrow: < 17 µs
Wide: > 13 µs
> 400 ns
Narrow: < 17 μs
Wide: > 13 μs
Minimum pulse/burst width for
envelope measurements
N/A N/A > 50 ns > 100 ns
Acquisition N/A N/A Auto, Manual
7
PRF, PRI range N/A N/A 1 Hz – 10 MHz 1 Hz - 5 MHz
Pulse detector response time
(typ)
8
N/A N/A 15 ns rise/fall 40 ns rise/fall
Pulse width accuracy N/A N/A 20 ns + (2*carrier period) 75 ns
Power ratio (typ) N/A N/A > 15 dB
Power range and sensitivity
(sinusoidal) (typ)
N/A N/A +13 dBm (1 Vrms) to
-13 dBm (50 mVrms)
< 3 GHz: +7 dBm (500 mVrms) to
-6 dBm (115 mVrms)
3 - 11 GHz: +9 dBm (630 mVrms) to
-8 dBm (90 mVrms)
> 11 GHz: +7 dBm (500 mVrms) to
-6 dBm (115 mVrms)
Measurement Characteristics (continued)
1. Maximum display resolution for frequency and period. Totalize display resolution is 15 digits, time interval based measurements are
12 digits.
2. Continuous, gap-free measurements limits the gate time setting to 10 µs to 1000 s in 10 µs steps.
3. Refer to the gate characteristics section for more details on advanced gate capabilities.
4. Measurements on each input channel are performed simultaneously using one gate interval. The actual measurement gate interval on each
channel will be synchrounous with edges of each input signal.
5. Maximum sample rate. Actual sample rate will be limited by the input signal edge rate for signals slower than the selected sample rate.
Maximum timestamp rate offers minimal FM tolerance. If high FM tolerance is required, use lower timestamp rates.
6. Assumes two frequencies are identical, only shifted in phase.
7. Manual control of gate width and gate delay are allowed only for wide pulsed mode.
8. For pulsed signals > -7 dBm (100 mVrms) while gated on.
9. For totalize, time interval and frequency measurements, you may get measurement readings beyond the range stated, but the accuracy of
those readings is not specied.
10. Applies when burst width * Carrier Freq > 80.
11. Specications apply if measurement channels are in 5 V range, DC coupled, 50 Ω terminated and at xed level for: time interval single and
dual channel, pulse width, duty, phase, single period and rise/fall time measurements.
12. Option 150 microwave pulse/burst measurement descriptions:
Burst carrier frequency
+ width burst (on)
- width burst (off)
PRI = 1/PRF
PRF
amplitude
p-p
- 6 dB
-6 dB Detector Level
(Option 106 only)
- width burst (off)
PRI = 1/PRF
PRF
- 12 dB
Burst carrier frequency
+ width burst (on)
-12 dB Detector Level
7 | Keysight | 53200A Series RF/Universal Frequency Counter/Timers - Data Sheet
购买、咨询产品请填写询价信息:(3分钟左右您将得到回复)
询价型号*数量*批号封装品牌其它要求
删除
删除
删除
删除
删除
增加行数
  •  公司名:
  • *联系人:
  • *邮箱:
  • *电话:
  •  QQ:
  •  微信:

  • 关注官方微信

  • 联系我们
  • 电话:13714778017
  • 周一至周六:9:00-:18:00
  • 在线客服:

天天IC网由深圳市四方好讯科技有限公司独家运营

天天IC网 ( www.ttic.cc ) 版权所有©2014-2023 粤ICP备15059004号

因腾讯功能限制,可能无法唤起QQ临时会话,(点此复制QQ,添加好友),建议您使用TT在线询价。

继续唤起QQ 打开TT询价