Plug-In Relays
Mini ISO Relays
Power Relay F4 / VF4
Please observe the disclaimer.
35
Catalog 1308028
Revision 03-06
Revision 03-05
Coil data
Available for nominal voltages 12, 24 V
Nominal power consumption of the unsuppressed coil at nominal voltage 1.6 W
Nominal power consumption at nominal voltage with suppression resistor 1.8/2.1 W (standard/high performance 24 V)
Test voltage winding/contact 500 VAC
rms
Ambient temperature range – 40 to + 125 °C
Operate time at nominal voltage Typ. 7 ms
Release time at nominal voltage
1)
Typ. 2 ms
1)
For unsuppressed relay coil
N.B.
A low resistive suppression device in parallel to the relay coil increases the release time and reduces
the lifetime caused by increased erosion and/or higher risk of contact tack welding.
Mechanical data
Cover retention
Axial force 150 N (33.8 lbs)
Pull force 200 N (45 lbs)
Push force 200 N (45 lbs)
Terminals
Pull force 100 N (22.5 lbs)
Push force 100 N (22.5 lbs)
Resistance to bending, force applied to front 10 N (2.25 lbs)
1)
Resistance to bending, force applied to side 10 N (2.25 lbs)
1)
Torsion 0.3 Nm
Enclosures
Dust cover Protects relay from dust. For use in passenger compartment or enclosures
Shrouded dust cover Protects relay and relay connector (order separately) from dust and splash
Weatherproof cover Mates with a connector (order separately) to seal relay from salt spray etc.
Recommended for under hood application
1)
Values apply 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved by more than 0.3 mm.
Operating voltage range