36
Assembly Instructions
FOR AMPHENOL STRAIGHT S.J. CLAMPS TO
DEF STAN 59-35 (Part 1) Sec. 3 FOR
INTERNALLY AND EXTERNALLY SCREENED AND UNSCREENED CABLES
INTERNALLY SCREENED JACKETED CABLE TYPE C
Cable and Wire Stripping
Strip the outer P.V.C. Jacket of the cable back to dim ‘A’ to expose the
internal braid. Trim the braid back to within 19.05mm (0.75 in) of
P.V.C. jacket and fold back ‘B’
A Dimension
Size
mm in
08
10
12 & 14
16 & 20
24
34.93
36.51
41.27
44.45
49.21
1.375
1.437
1.625
1.750
1.937
FOR 162 SERIES
Strip 5.6
mm (0.220 in) to 6.6mm (0.260 in) of insulation from each wire
taking care not to cut or nick strands. If ends fray twist them back to
their original lay.
INITIAL ASSEMBLY
Slide onto the cable the following items in this order (1) Nut (2) Washer
(3) Gasket (4) Braid Clamp and (5) Clamp Body
CRIMP CONNECTION TO CONTACTS (162 SERIES)
Using the recommended tools, crimp the contacts to the wires and
insert them in the connector as described in the Amform instructions,
which are supplied with each 162 series assembly.
Bring up clamp body taking care not to drag the braid forward. (If
necessary a small amount of thin tape may be used to hold the braid
in position whilst carrying out this operation). Screw the clamp body
onto the connector accessory thread, making sure that the connector
serrations engage with those on clamp body. Fold the braid out at
right angles to the cable and slide forward the braid clamp. Smooth
back braid onto the braid clamp and trim off the surplus. Slide up
gasket, washer, screw on nut and tighten.
Surplus Braid
Trimmed