https://www.phoenixcontact.com/pi/products/1407280
08/29/2018Page3/4
Sensor/actuator cable-SAC-8P-M12MS/ 5,0-28X SH OD-1407280
Technical data
Cable
Minimum bending radius, fixed installation 5 x D
Minimum bending radius, flexible installation 10 x D
Number of bending cycles 1000000
Minimum bending radius, drag chain applications 10 x D
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 10 m/s²
Cable weight 81 kg/km
Outer sheath, material PE-X
Material, inner sheath PE-X
Material, filler PP yarn
Material conductor insulation PE-X
Conductor material Bare Cu litz wires
Insulation resistance ≥ 100 MΩ*km (at 20 °C)
Conductor resistance ≤ 78 Ω/km (at 20 °C)
Working capacitance approx. 80 pF (core-core)
approx. 125 pF (core-shield)
Nominal voltage, cable ≤ 300 V AC
Test voltage, cable ≥ 3000 V AC (Spark test)
Test voltage Core/Shield ≥ 1000 V AC (for 10 s)
Special properties Inductance approx. 0.48 mH/km
Irradiated
Flame resistance According to DIN EN 60332-1-2
according to DINEN50266-2-5
Halogen-free in accordance with DIN VDE 0472 part 815
in accordance with DINEN50267-2-1
Resistance to oil According to DIN EN 60811-2-1, 168 h at 100°C
According to DIN EN 50306
Other resistance Resistance to fuels according to IEC 60811, 168 h at 70°C
UV resistant according to DIN VDE 0276-605
Ambient temperature (operation) -40 °C ... 105 °C (cable, fixed installation)
-15 °C ... 105 °C (cable, flexible installation)
20 °C ±5 °C (cable, drag chain applications)
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings