advanced-energy.com 3
ULTRAVOLT AA SERIES
Parameter Conditions Models Units
Output 1AA 2AA 4AA 6AA
Voltage Range Nominal Input 0 to 1000 0 to 2000 0 to 4000 0 to 6000 VDC
Nominal Input Voltage/Model 12 24 24 12 24 24 12 24 24 12 24 24 VDC
Power Nominal Input,
Max Eout
4 20 30 4 20 30 4 20 30 4 20 30 W
Current Iout Entire Output
Voltage Range
4 20 30 2 10 15 1 5 7.5 0.67 3.3 5 mA
Current Scale
Factor
Full Load 0.37 4.60 4.62 0.192 1.52 1.52 0.090 0.752 0.76 0.066 0.490 0.50 mA/V
Voltage Monitor Scaling 100:1 ±2% into 10 MΩ -
Ripple Full Load, Max Eout 0.026 0.048 0.073 0.01 0.011 0.046 0.042 0.050 0.070 0.035 0.024 0.046 %V
pk to pk
Line
Regulation
Nom. Input, Max
Eout, Full Power
< 0.01% VDC
Static Load
Regulation
No Load to Full Load,
Max Eout
< 0.01% VDC
Stability 30 Min Warmup,
Per 8 h, Per Day
< 0.01%/< 0.02% VDC
Programming and Controls All Types
Input
Impedance
Nominal Input +output models 1.1 MΩ to ground, - output models 1.1 MΩ to +5 vRef. MΩ
Adjust
Resistance
Typical
Potentiometer
Values
10 to 100 K (potentiometer across vRef. and signal ground, wiper to adjust) Ω
Adjust Logic 0 to +5 for +Out,
+5 to 0 for - Out
+4.64 VDC for +output or +0.36 for -output = nominal Eout -
Output
Voltage and
Impedance
T = +25°C +5.00 VDC ±2%, Zout = 464 Ω ±1% -
Enable/Disable 0 to +0.5 disable, +2.4 to 32 enable (default = enable) VDC
Environmental All Types
Operating Full Load, Max Eout,
Case Temperature
-40 to +65 °C
Coefficient Over the Specified
Temperature
±50 (±25 optional) PPM/°C
Thermal
Shock
Mil-Std 810, Method
503-4, Proc. II
-40 to +65 °C
Storage Non-Operating,
Case Temperature
-55 to +105 °C
Humidity All Conditions,
Standard Package
0 to 95%, non-condensing -
Altitude Standard Package,
All Conditions
Sea level through vacuum -
Shock Mil-Std-810, Method
516.5, Proc. IV
20 Gs
Vibration Mil-Std-810, Method
514.5, Fig.514.5C-3
10 Gs
ELECTRICAL SPECIFICATIONS (CONTINUED)