2 advanced-energy.com
ULTRAVOLT AA SERIES
ELECTRICAL SPECIFICATIONS
Parameter Conditions Models Units
Input 12 V 24 V
Voltage Range Full Power +11 to 16 +23 to 30 VDC
Voltage Range Derated Power
Range
+9 to 32 +9 to 32 VDC
Current Standby/Disable < 30 < 30 mA
Current No Load, Max Eout < 100 (4 W) 150 (20 and 30 W) mA
Current Max Load, Max Eout < 450 (4 W) < 1000 (20 W)
< 1500 (30 W)
mA
AC Ripple
Current
Nominal Input,
Full Load
< 80 < 80 mA pk
to pk
Output 1/16AA 1/8AA 1/4AA 1/2AA
Voltage Range Nominal Input 0 to 62 0 to 125 0 to 250 0 to 500 VDC
Nominal Input Voltage/Model 12 24 24 12 24 24 12 24 24 12 24 24 VDC
Power Nominal Input,
Max Eout
4 20 30 4 20 30 4 20 30 4 20 30 W
Current Iout Entire Output
Voltage Range
64 320 480 32 160 240 16 80 120 8 40 60 mA
Current Scale
Factor
Full Load 42.67 969.7 960 11.64 237 258 3.27 70.48 72.7 0.79 17.78 17.65 mA/V
Voltage Monitor Scaling 10:1 ±2% into 10 MΩ -
Ripple Full Load, Max Eout 0.03 0.06 0.15 0.03 0.038 0.038 0.023 0.04 0.05 0.01 0.01 0.011 %V pk
to pk
Line
Regulation
Nom. Input, Max
Eout, Full Power
< 0.01% VDC
Static Load
Regulation
No Load to Full Load,
Max Eout
< 0.01% VDC
Stability 30 Min Warmup,
Per 8 h, Per Day
< 0.01%/< 0.02% VDC