功能描述: Relay for Energy Flow EFR4000IP Optimization of consumption of own energy Integrated Webserver, IP-Connection, Zero Export Device, measuring transducer for power
PDF文件大小: 736.09 Kbytes
PDF页数: 共2页
制造商: ZIEHL[ZIEHL industrie-elektronik GmbH + Co KG]
制造商LOGO: ZIEHL[ZIEHL industrie-elektronik GmbH + Co KG] LOGO
制造商网址: https://www.ziehl.com
捡单宝S225761
PDF页面索引
120%
114
ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de
economical to consume the excess energy self. This
is especially reasonable when the dierence is high
between the price you pay to the grid provider and the
price the provider pays for fed in energy.
Functions:
Shift own consumption into times with high gene-
ration of energy
Switch on consumers when you have overow of
energy
Increase the share of consumed own energy
intelligent control of consumers
Cheap equipment costs ensure a short payback period:
Save € 312 * a year with the EFR4000IP by switching on at 200 days a year for an
average 3 hours consumers with 4 kW in times you have a surplus of own energy.
Equipment costs (EFR4000IP, 3x current transformer, if necessary contactors) are returned
within about 2 years*.
Longer / shorter switch on times and larger / smaller consumption shorten / extend
the period. In addition, in the long term rising purchase prices for energy can be expected.
* Feed 12 Ct / kWh, electricity purchase price 25 Ct / kWh
Relay for Energy Flow EFR4000IP
Optimization of consumption of own energy
Integrated Webserver, IP-Connection, Zero Export Device, measuring
transducer for power
Relays for energy ow EFR4000IP
monitor the current ow between
public power grid and generating
plant / consumer.
Operation is made comfortably
via integrated webserver or di-
rectly at the device. Measured
values are displayed neatly
arranged at device on monitor.
When the own power plant
generates more power than ac-
tually is consumed it often is more
The EFR measures the energy ow
in all 3 phases and calculates the
mean value.
Is sucient own power left, the
EFR4000IP switches on up to three
consumers and ensures that the
power is consumed in the house.
This is relatively simple if a PV system
feeds uniformly under a clear sky
and consumers with constant power
consumption, such as heat pumps
or heating elements, are connected.
Particularly suitable are consumers
that consume a lot of energy and can
be switched frequently, for example
boilers.
It becomes more complicated when
the generation varies because of
clouds before the sun and consumers
do not continuously draw current as
washers, dryers, irons or stoves.
The analog output can regulate a
consumer stepless and thus achieve
a yet higher rate of own consumption.
When using phase angle controls the
specications of the grid providers
have to be obeyed.
Energy ow is always evaluated
and displayed, as seen from a po-
wer meter for purchasing energy:
purchase from public grid is positive,
fed in energy reduces the bill and is
therefore negative (- sign).
The EFR4000IP can optimize the
consumption of own energy even
under dicult conditions.
Features and functions:
Switching of up to 3 consumers: the largest consumer, ranked 1-2-3 or combination of
3 consumers (7 levels)
Power consumption of the connected consumers
Switch on points. At which energy ow consumers are switched on
Switch on delay of consumers. Short lowering in consumption (by clocking consumers)
or peaks in the feed does not immediately cause turn on of additional consumer
Minimum on time. Heat pumps may not be switched on and o permanently, washing
machines should be able to complete a cycle.
Switch o delay. Short consumption peaks or reduction of the generated energy does
not immediately switch o a load.
Switch o point. At which energy ow consumers are switched o again. In practice,
this value is usually slightly on the purchase side.
Inputs for blinding out consumers when these are not available, for example when boiler
has reached maximum temperature.
Control of heat pumps (SG-ready), battery chargers, inverters
Relay for Plants for Generation of own
Leistung [kW]
4:00 6:00 8:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00
Feed in
Heat pump
Examples additional consumption with EFR3000Energy Flow:
Purchase
Own consumption without EFR3000 Air conditioner
Heater for water, regulated
Heater for water, not regulated
2017-08-21
EFR4000IP
Part numbers:
EFR4000IP S225761
Suitable current transformer (split
core): 60/1A, class 3 0,4 VA
KBR 18S S225770
Suitable mini current transformer:
64/1A, class 1 0,5 VA
CTM7 S225780
购买、咨询产品请填写询价信息:(3分钟左右您将得到回复)
询价型号*数量*批号封装品牌其它要求
删除
删除
删除
删除
删除
增加行数
  •  公司名:
  • *联系人:
  • *邮箱:
  • *电话:
  •  QQ:
  •  微信:

  • 关注官方微信

  • 联系我们
  • 电话:13714778017
  • 周一至周六:9:00-:18:00
  • 在线客服:

天天IC网由深圳市四方好讯科技有限公司独家运营

天天IC网 ( www.ttic.cc ) 版权所有©2014-2023 粤ICP备15059004号

因腾讯功能限制,可能无法唤起QQ临时会话,(点此复制QQ,添加好友),建议您使用TT在线询价。

继续唤起QQ 打开TT询价