147
ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de
Level Monitors
is transmitted via signal 4-20 mA (2 wire).
The cable (PUR) includes a pressure compensation
capillary that compensates uctuation of atmospheric
pressure.
Applications:
Gasoil, diesel, used oil
Engine oil and lube oil (fresh)
Rainwater in cisterns, basins and water levels in
general
Standard probe NS6123-6
0-250 mbar, cable 6 m
Economy-priced probe with in-
tegrated measuring transducer
for measuring lling level e.g. in
tanks, cisterns or waters.
Connection to ZIEHL-Web-Relay
TR800Web for monitoring and
logging of lling levels. Alarms by
emails when levels are reached,
e.g. before tank is empty.
Monitoring and display of levels
with Digital Panelmeters MINI-
PAN 352 or other devices with
input 4-20 mA.
The probe for relative pressure
is submersible. It is placed at the
bottom of the tank and determi-
nes the level by measuring the
hydrostatic pressure. The result
•
•
•
2016-12-22
Connection to Universal Web-Relay Type TR800Web
Scaling of TR800Web for water:
Scaling of TR800Web for oil:
Filling level probe Type NS6123-6
for measuring filling level of water and gasoil
0 - 250 mbar, integrated measuring transducer
Water (density 1,0): 1 mbar = 1 cm
0...250 mbar correspond to level 250.0 cm
Oil (density 0,82...0,95): 1 mbar = 1/density cm
Example density 0,862: 1 mbar = 1,160 cm
0...250 mbar correspond to level 0,0...290 cm
Density of liquid can be calculated by using signal of probe and measuring depth of immersion with a meter stick.
Filling level probe
NS6123-6
Part number: V223470