GP1U58Y Series
GP1U58Y Series
■ Outline Dimensions
(
Unit : mm
)
■ Features
■ Applications
■ Absolute Maximum Ratings
(
Ta= 25˚C
)
■ Recommended Operating Conditions
*1 No dew formation
*2 For 5 seconds
1. Less sensitive to a fluorescent lamp driven
by inverter
13.25
3.6
2
3.65
❈ 1
7.5
❈ 1
15
Rib
❈ 2
2.542.542.1
❈ 2 ❈ 2 ❈ 2
14.2 1.4
2.4
2.54
1.72.54
4.3
12 3
12 3
3 GND
1 Vout
2 Vcc
❈ 1 Detector center
❈ 2 The dimension of connector base
3. Built-in voltage regulator circuit
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device. ”
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
Remote Control
Parameter Symbol Value Unit
Supply voltage V
CC
4.7 to 5.3 V
Parameter Symbol Rating Unit
Supply voltage
V
CC
0 to 6.3 V
*1
Operating temperature
T
opr
- 10 to + 70
˚C
Storage temperature T
stg
- 20 to + 70
˚C
*2
Soldering temperature
T
sol
260 ˚C
IR Detecting Unit For
2. Various B.P.F.
(
Band Pass Filter
)
frequency
* Tolerance:± 0.3mm
from the soldering face.
Recommended drilling as viewed
3-
φ
0.8
5.5
± 0.5
15.4
+
0.5
-
0.3
1. TVs
2. VCRs
3. Audio equipment
4. Air conditioners
5. CATV set top boxes
6. BS receivers
7. Multi-media equipments