Output current derating (current is total value of CH1 to CH6)
ALD-25
・
All specifications are subject to change without notice.
ALD-605012P
*
131
ALD-605012P*131
Specifications
(Please refer to each specification before use)
MEASURE FA SEMI
LED driver
Others
Others
MED
(*5) Note that with parallel connections, the greater the disparity between each string voltage
(the total Vf in each string) the greater the amount of heat generated by the activated IC.
Please use the same products for each string of LEDs and, likewise, use the same serial
connections.
DIP type
:
ALD-605012PD131
SMD type
:
ALD-605012PS131
Constant Current DC-DC Convertor
for LED
■
Featur
es
●Six Outputs
●Compact, high efciency
●Usable in a wide range of temperatures
●
Applicable panel size: 6 to 12 inches (rough guide)
●Combined use of PWM modulated light and analog modulated
light (ADIM) assur
es universality
●
Equipped with load (LED) open detection (alarm output) function
●Onboard and connectorless
●Wide dimming range
■
Applications
Electrical Characteristics
Item Unit Symbol
Specication Condition
min. typ. max. Vin(V) Vrmt(V) Vpwm(%) Rbr(kΩ) Ta(℃) RL1-6(Ω)
Remarks
Output
Current
mA
Iout1-6 (Maximum
dimmer)
40 50 60 12±1. 2 5±0.25 100 10 -20to55 600
(*1)
Iout1-6 (when
modulating light)
3 5 7 12±1.2 5±0.25 10 10 -20to80 600
PWM modulated light (*1)(*2)
10 20 30 12±1.2 5±0.25 100 1 -20to80 600
ADIM modulated light (*1)(*2)
Input
Current
A Iin1
- 0.9 1.2 12±1.2 5±0.25 100 10 -20to80 600
Remote ON
mA Iin2
- - 10 12±1.2 0 100 10 -20to80 600
Remote OFF
Modulated
light frequency
Hz F
180 225 270 12±1.2 5±0.25 10 10 -20to80 600
Alarm
Signal
V Vst
- - 1 12±1.2 5±0.25 100 10 -20to80 600
On a normal operation (*3)
4.5 5.0 5.5 12±1.2 5±0.25 100 10 -20to80 ∞
In case of lamp anomaly (*3)
(*1) When output is open, the output voltage of that series is restricted, and other series operate normally.
(*2) See “Connections” as well as “Analog Modulation Light (ADIM) and PWM Modulation Light” for details about modulation light.
(*3) See “Connections” for details about alarm output.
(*4) These dimensions are indicated the maximum only H. Others are typical values.
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specic bromine-based ame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■
Conformity to RoHs Directive
Other Specifications
Modulated light system
PWM/ADIM (*2)
Operating Temperature
℃ -30 to +80(with current derating)
Storage Temperature
℃ -40 to +85
Operating Humidity Ratio
RH% 95Max
Weight
g 5.5 typ.
Dimensions (WxDxH)
mm
22.86x21.1x8.5(DIP)(*4)
26.16x21.1x8.8(SMD)(*4)
Fused Input No
Remote ON / OFF Yes
Lamp open detection function Yes
web180528