ABB Switzerland Ltd, Semiconductors reserves the right to change specifications without notice.
V
RRM
=
5500
V
I
F(AV)M
=
175
A
I
FSM
=
3×10
3
A
V
(T0)
=
3.35
V
r
T
=
7.2
mΩ
V
DC-link
=
3300
V
Fast Recovery Diode
5SDF 02D6004
PRELIMINARY
Doc. No. 5SYA1118-02 Okt. 02
• Patented free-floating technology
• Industry standard housing
• Cosmic radiation withstand rating
• Low on-state and switching losses
• Optimized for snubberless operation
Blocking
Maximum rated values
1)
Parameter Symbol Conditions Value Unit
Repetitive peak reverse voltage V
RRM
f = 50 Hz, t
p
= 10ms, T
vj
= 115°C 5500 V
Permanent DC voltage for 100 FIT
failure rate
V
DC-link
Ambient cosmic radiation at sea level in open
air. (100% Duty)
3300 V
Permanent DC voltage for 100 FIT
failure rate
V
DC-link
Ambient cosmic radiation at sea level in open
air. (5% Duty)
3900 V
Characteristic values
Parameter Symbol Conditions min typ max Unit
Repetitive peak reverse current I
RRM
V
R
= V
RRM
, T
vj
= 115°C 20 mA
Mechanical data
Maximum rated values
1)
Parameter Symbol Conditions min typ max Unit
Mounting force F
m
14 16 18 kN
Acceleration a
Device unclamped 50 m/s
2
Acceleration a
Device clamped 200 m/s
2
Characteristic values
Parameter Symbol Conditions min typ max Unit
Weight m
0.25 kg
Housing thickness H
26.0 26.6 mm
Surface creepage distance D
S
30 mm
Air strike distance D
a
20 mm
Note 1 Maximum rated values indicate limits beyond which damage to the device may occur