REVISIONS
LTR DESCRIPTION DATE (YR-MO-DA) APPROVED
A
Add case outline 2 for device types 01 and 02. Update format. Editorial
changes throughout.
89-11-07
M. A. Frye
B
Changes to large-signal voltage gain test and to the output voltage swing test.
Changes IAW NOR 5962-R193-93.
93-08-26
M. A. Frye
C
Add case outline K. Change boilerplate t o add one-part part numbers. Add
delta test limit s. Redrawn.
96-11-25
R. Monnin
D
Add radiation hardness requirements. Updat e boilerplate. -rrp
98-06-19
R. Monnin
E
Change to the slew rate test condition A
VCL
in table I. -rrp
00-10-04
R. Monnin
F
Add case outline D. Remove radiation exposure circuit. Changes made to
1.2.4, 1.3, 3.2.3, figure 1, and t able IIA. Update boilerplate to reflect current
requirements. -rrp
03-03-19
R. Monnin
THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED.
REV
SHEET
REV
SHEET
REV STATUS REV F F F F F F F F F F F
OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11
PMIC N/A PREPARED BY
Gary Zahn
DEFENSE SUPPLY CENTER COLUMBUS
STANDARD
MICROCIRCUIT
DRAWING
CHECKED BY
Ray Monnin
COLUMBUS, OHIO 43216
http://www.dscc.dla.mil
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
APPROVED BY
Michael A Frye
MICROCI RCUIT, LINEAR, RADIATION
HARDENED, LOW NOISE, QUAD OPERATIONAL
AMPLIFI ERS, MONOLITHIC SILI CON
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
DRAWING APPROVAL DATE
88-08-18
AMSC N/A
REVISION LEVEL
F
SIZE
A
CAGE CO DE
67268
5962-88565
SHEET
1 OF
11
DSCC FORM 2233
APR 97 5962-E298-03
DISTRIBUTION STATEMENT A
. Approved for public release; distribution is unlimited.