May 2006 Rev 7 1/8
8
Z04
Standard
4 A Triacs
Main features
Description
The Z04 series is suitable for general purpose AC
switching applications. They can be found in
applications such as home appliances
(electrovalve, pump, door lock, small lamp
control), fan speed controllers,...
Different gate current sensitivities are available,
allowing optimized performances when controlled
directly from microcontrollers.
Order codes
Symbol Value Unit
I
T(RMS)
4A
V
DRM
/V
RRM
600 to 800 V
I
GT (Q
1
)
3 to 25 mA
Part Number Marking
Z04xxyF
(1)
1. xx = sensitivity, y = voltage
Z04xxyF
(1)
A2
A1
G
G
A1
A2
TO202-3
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
I
T(RMS)
RMS on-state current (full sine wave)
T
amb
= 25° C
4A
T
l
= 30° C
I
TSM
Non repetitive surge peak on-state current
(full cycle, T
j
initial = 25° C)
F = 50 Hz t = 20 ms 20
A
F = 60 Hz t = 16.7 ms 21
I
²
tI
²
t Value for fusing t
p
= 10 ms 2.2 A
²
s
dI/dt
Critical rate of rise of on-state current I
G
=
2 x I
GT
, t
r
≤ 100 ns
F = 120 Hz T
j
= 125° C 20 A/µs
I
GM
Peak gate current t
p
= 20 µs T
j
= 125° C 1.2 A
P
G(AV)
Average gate power dissipation T
j
= 125° C 0.2 W
T
stg
T
j
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
° C
www.st.com