Isolated H-Bridge Transformers for MAX13256
Note: This datasheet might be slightly modified without notice in order to improve the quality and reliability of the product. Please
contact an appropriate our sales in your regions for checking final spec before you place an order Rev. .1.0(2014.04)
2.54
11.0
18.0
1.5
◆
Outline
・RoHS compliance
・MSL level1
・Operating temperature range : -40℃~+85℃ (Including coil’s self temperature rise)
・Packing : Tape & Reel, 350pcs par reel.
◆
Applications
・Isolated H-Bridge Transformer for MAX 13256 reference. Power Meters, Isolated Fieldbus Interfaces,
24V PLC Supply Isolation, Medical Equipment, Motor Controls.
◆ Sumida Type name : CPFC1209
◆
Dimensions (mm)
Stamp
◆ Recommend PCB layout (mm) Coil Connection (Bottom View)
◆ Electrical characteristic
Part Number
Stamp
(
*
1)
Inductance
(1-5)
10KHz,0.1Vrm
DCR
(1-5)
DCR
(6-9) / (7-10)
Turns ratio
(1-5) : (6-9) : (7-10)
Hi pot (1,5) -
(6,7,9,10)
ET
(1-5)
05220-T009 009 750mΩ Max. 750mΩ Max. 2 : 1 : 1
05220-T010 010 750mΩ Max. 750mΩ Max. 1 : 1 : 1
05220-T011 011 300 µH Min. 750mΩ Max. 650mΩ Max. 3 : 2 : 2
35.0V. μS
Min.
05220-T012 012 300 µH Min. 1.2 Ω Max. 1.2 Ω Max. 1 : 1 : 1
(
*
2)
05220-T013
013 750 µH Min. 700mΩ Max.
(6 - 10)
250mΩ Max.
(1- 5) : (6-10)
3 : 1
5000Vrms
1 Sec
50/60Hz,
1mA
60.0V. μS
Min.
2000Vrms
1 Sec
50/60Hz,
1mA
60.0V. μS
Min.
750 µH Min.
* Dots indicate the polarity.
10
13.5 Max.
6
1 5
10.0 Max.
SQ0.5
2.54±0.3
1 5
610
T007
sumida
Stamp·Date Code
*1
*2 (05220-T013 Only)
05220-T009 ~T012